BFS-PGE-50S4 Release Notes
Product Information
Product: BFS-PGE-50S4
Device Version: 2.1.2
Firmware Version: 2609.0000.005.000
Bugs Fixed
| Bug | Version | Description |
|---|---|---|
| F-6730 | 2.0.0 | Camera entered a state which could not send out image data after a packet storm. |
| F-13585 | 2.0.0 | User load resulted in node values not being set properly. |
| F-13590 | 2.0.0 | Shading Correction error resulted in a white line down the right side of the image. |
| F-14089 | 2.0.0 | Camera reset required to make persistent IP settings valid. |
| F-15210 | 2.1.0 | PTP Master entered reset mode which could result in a large time offset on slave cameras. |
| F-15307 | 2.1.2 | Default value of node "AcquisitionImageTimestamp" was "StartOfExposure" and is now "EndOfExposure". |
Changes
| Change | Version | Description |
|---|---|---|
| F-9819 | 2.0.0 | Support Firmware Feature release in Device Version. |
| DEVP-91 | 2.1.0 | Asynchronous Auto Algorithms are optimized to support higher frames rates. |
| DEVP-331 | 2.1.0 | The BFS product family is GigE Vision 2.0 compliant. This firmware requires GigE Vision 2.0 compliant software on the host. Spinnaker 3.1 or later is required. |
| DEVP-332 | 2.1.0 | Immediate action command execution delay time is improved from approximately 400us to a maximum of one line time. Scheduled action commands are now executed within one line delay of the scheduled time. |
| DEVP-334 | 2.1.0 | PTP accuracy was increased from 10us down to less than 1us. |
| DEVP-391 | 2.1.0 | Camera generated action command feature provides a mechanism for the camera to generate an action command on the ethernet interface with very low latency when a user configurable event occurs. |
| F-15282 | 2.1.1 | Add buffered burst and disable by default. |
| F-15027 | 2.1.0 | Dynamic image buffers are now supported, providing additional image buffers for full image and ROI configurations to allow the camera to continue acquiring images when the host is not reading the images from the camera fast enough or when the acquisition is faster than the interface speed (like buffered burst). |
Known Issues
| Issue | Version | Description |
|---|---|---|
| F-14983 | 2.1.0 | Lossless compression may result in a missing packet error when chunk data is enabled. This is a Spinnaker GEV 2.0 incompatibility. |